Selamat datang di website
SARANA MEDIKA SEJAHTERA (PT.SARANA MEDIKA SENTOSA)

SYRINGE PUMP TERUMO TE 331

  • Harga
    ≥ 1 16.000.000
  • Min Pembelian 0
  • Satuan
  • Update Terakhir10/01/2016
  • Formulir Pemesanan
  • Jumlah
  • Pesan

Info Produk

SYRINGE PUMP TERUMO TE 331 TERUMO JUAL SYRINGE PUMP TERUMO TE 331 cOnTAK : 085771299222 rIO sarana medika sejahtera adalah toko alat kesehatan terlengkap dan dengan harga yang sangat bersaing terutama merek GEA, TERUMO, SHARP, ONEMED, OMRON, ALSA, RIESTER, PRIMEDIC Dll SYRINGE PUMP TERUMO TE 331 / JUAL Specifications Product Name TERUFUSION Syringe Pump TERUFUSION Syringe Pump ( with Body Weight Mode) Compatible Syringes 10, 20, 30 and 50 mL ( TERUMO and specified brands) Range of Flow Rate Setting 0.1-300 mL/ h ( for 10, 20 and 30 mL syringes) 0.1-999 mL/ h ( for 50 mL syringes) 0.1-1200 mL/ h ( special function for 50 mL syringes) Flow Rate Display Change 0.1 mL/ h steps ( for settings from 0.1 to 99.9 mL/ h) 1 mL/ h steps ( for settings from 100 to 999 mL/ h) Flow Rate Accuracy Mechanical Accuracy: ± 1% Accuracy including syringe: ± 3% Occlusion Detection Pressure Selectable from three levels. ( Values are with use of TERUMO syringe) [ III] : 800 ± 200 mmHg max. ( 106.7 kPa ± 26.7 kPa) [ II] : 500 ± 100 mmHg max. ( 66.7 kPa ± 13.3 kPa) [ I] : 300 ± 100 mmHg max. ( 40 kPa ± 13.3 kPa) Optional: 5 occlusion levels ( 100, 200, 300, 500 and 800 mmHg) Priming ( purge rate) 300 mL/ h ~ 1200 mL/ h ( Depending on syringe size) Alarms Occlusion, Nearly empty, Low Battery, Plunger/ Clutch disengaged, Syringe disengaged, AC/ DC Cable disconnected. High flow warning when turning the dial over 10 mL/ h ( optional) Special Functions Functions are selectable via internal switches: • Delivery Limit setting 0.1 – 999.9 mL ( in 0.1 mL steps) When the limit is reached, an alarm will occur and the infusion will continue at KVO rate of 0.1 mL/ h. • Nearly Empty alarm setting The time until the syringe is empty can be programmed. ( from 3 to 60 min.) • Max. Flow Rate 1 – 1200 mL/ h ( in 1 mL steps) • Syringe Brand Confirmation • Memory function ( last settings) • Changeable flow rate during infusion Power Supply 100 to 240 VAC, 50/ 60 Hz 12 to 15 VDC Operable duration using internal battery NiMH: Approx. 5 hours ( using a new battery at flow rate of 5 mL/ h and ambient temperature of 25° C, after charging at least 15 hours with the power off) Classification ( acc. to IEC 60601-1) Class I and internally powered equipment, Type CF, Continuous operation, IPX4 ( splashproof) External Dimensions 322 ( W) x 114 ( H) x 115 ( D) mm Weight TE-331 ± 1.8 kg TE-332 ± 1.9 kg External Communication and Nurse Call Connector Customer Support : Pin BB : 76981BE8 ( Marketing) 7E98EE0A ( Big Boss)